Issue:
Customer reports an E19 error on the treadmill. This may relate to the incline adjustment mechanism or the running belt operation.
Safety Reminder:
Before disassembling any treadmill parts to inspect internal wiring, please ensure the treadmill is completely powered off and wait at least 5 minutes to ensure complete power discharge.
Tools You May Need
- Pliers
- Alcohol
- Screwdriver
Possible Operations
- Removing the motor cover
- Removing hot-melt glue from terminal clips
Motor cover removal video:
How to Remove the Motor Cover – Video Guide
Tip for removing hot-melt glue on the cable terminal :
Apply a small amount of alcohol to the hot-melt glue, then carefully remove it with pliers.
Step 1 – Preliminary Check
Confirm whether the incline adjustment buttons and running belt can operate normally.
Step 2 – If the Incline Buttons Work, but the Belt Does Not Start
Perform incline calibration:
Remove the safety key.
Press and hold the Incline Down button and Speed 8 button simultaneously for 3–5 seconds until a long beep sounds.
Re-insert the safety key.
The treadmill motor will automatically perform a complete incline calibration cycle.
-
Check if the error is cleared.
If cleared → treadmill should function normally.
If not cleared → proceed to Step 2.
Step 3 – If Incline Buttons Do Not Work and Belt Cannot Start
Unplug the treadmill and ensure it is completely powered off for at least 5 minutes.
Open the motor cover (refer to the attached video).
Locate the terminal indicated by the green arrow in the diagram.
-
Carefully reconnect the terminal:
The terminal may have glue applied during production.
Clean the terminal with a cloth slightly dampened with alcohol to soften the glue before reconnecting.
After reconnecting the terminal, power on the treadmill and perform the incline calibration as described in Step 1.
-
Check if the treadmill operates normally.
-
If still abnormal → consider control board failure or linear actuator (incline motor) failure.
-
Solution / Recommendation:
In most cases, restarting the treadmill after unplugging it from the power outlet resolves the E19 error.
If the issue persists after following the steps above, please submit a service ticket to get support from our customer service team. You can submit your request here: Submit a service ticket.
-
When submitting a ticket, please provide:
Your order number
Product SN number
Any relevant photos or videos
If performing the above steps is difficult, you can also submit a ticket directly and our support team will assist you.
Notes / Tips
Always remove the safety key before performing calibration.
Ensure terminals are clean and free of debris before reconnecting.
Perform all steps carefully to avoid damaging the motor or control board.